en | Configuring the HD Conference Dome
HD Conference Dome
F.01U.265.806 | 1.0 | 2012.03
Installation Manual
Bosch Security Systems, Inc.
Telnet support
If you want to allow only secure connections with encrypted
data transmission, you must select the
Off
option to deactivate
Telnet support. The unit will then no longer be accessible using
the Telnet protocol.
Interface mode ETH
If necessary, select the Ethernet link type for the
ETH
interface.
Depending on the unit connected, it may be necessary to select
a special operation type.
Network MSS (Byte)
You can set the maximum segment size for the IP packet's user
data. This gives you the option to adjust the size of the data
packets to the network environment and to optimize data
transmission. Please comply with the MTU value of 1,514 bytes
in UDP mode.
iSCSI MSS (Byte)
You can specify a higher MSS value for a connection to the
iSCSI system than for the other data traffic via the network. The
potential value depends on the network structure. A higher
value is only useful if the iSCSI system is located in the same
subnet as the HD Conference Dome.
Enable DynDNS
DynDNS.org is a DNS hosting service that stores IP addresses in
a database ready for use. It allows you to select the HD
Conference Dome via the Internet using a host name, without
having to know the current IP address of the unit. You can
enable this service here. To do this, you must have an account
with DynDNS.org and you must have registered the required
host name for the unit on that site.
NOTICE!
Information about the service, registration process and
available host names can be found at DynDNS.org.