RE 92076-01-B/2021-04-22, Bosch Rexroth AG
Troubleshooting |
A4... with HS5E(V)(L) control system Series 1x and 30 93
/104
14.2 Error/diagnosis memory
For diagnosis purposes, the HS5E(V)(L) control system is fitted with an internal
error and diagnosis memory. To open the error memory, select
"Diagnosis"
→
"Diagnosis memory".
Fig. 34: Error/diagnosis memory
14.2.1 Fault diagnosis
At pin 3 of the central connector the signal "drive ready" can be output. For this,
the factory assignment of the digital output to parameter P-0-0115, bit 1 must be
activated. This signal can be used to find out whether control is active and that no
fault message is present. Should a fault message occur during operation or the
controller enable be withdrawn, this bit is set to 0.
Here, the following applies:
Table 26: Messages
Meaning of the message
Output signal at pin 3
Electronics OK
24 V
Fault message present or no controller
enable set
0 V