Commissioning
Logamatic EMS – 6 720 801 387 (2011/05)
22
5
5.3
Quick start-up (quick programmer menu)
B
Press
button to open the
quick operation
menu.
SHORTPROG\
Menu item
Input range
Standard
setting
Other information
LOW LOSS
HEADER
Have you installed a
module for the
hydraulic low loss
header?
Yes, No
no
In association with
MCM10 the setting is
automatically set to
“Yes”the screen is
hidden.
1)2)
Is a sensor for the low
loss header
connected?
No, at the
boiler, at the
low loss
header
module
no
If a low loss header
module is used, connect
the temperature sensor
to the low loss header
module.
3)
SYSTEM
Is heating circuit 1
installed (unmixed
heating circuit)?
Yes, No
Yes
NO. OF MIXERS
How many mixed
heating circuits are
installed?
0 to 3
0
Set the address on the
rotary coding selector of
the mixer module (basic
setting HK2).
1)
HEATING CIRCUIT
1
(and other heating
circuits)
Which operating unit
is assigned to heating
circuit 1?
RC2x/
RC20/RF,
RC35, none
RC35
Assigning programming
units to heating circuits
(
Æ
page 35). General
heating circuit data (
Æ
page 31).
Set up any other heating
circuits as per heating
circuit 1.
How should heating
circuit 1 be
controlled?
Outside
temperature
compensate
d, room
temperature
compensate
d
Outside
temperatur
e
compensat
ed
Which heating system
does heating circuit 1
have?
Radiator,
convector,
floor
Radiator
Heating curve (
Æ
page 36)
Table 9
Quick programmer menu navigator
SERVICE MENU
B
quick operation
settings
diagnosis
servicing