Product information
Logamatic EMS – 6 720 801 387 (2011/05)
10
2
2.7
Replacement of ERC with RC35
Topic
ERC
RC35
Note
See page
Setback modes
(night setback)
Changeover
between
“Shutdown” and
“Outdoor setback
mode” subject to
the selected outside
temperature
threshold.
Selection of four
setback modes:
• Reduced
operationShut-
down
modeRoom
setback
modeOutdoor
setback mode
Deviation, e.g.
modified outside
temperature
threshold for outside
setback mode.
Settings at the
RC35 programming
unit possible as for
the ERC – requires
clarification with the
end user.
37 – 38
HS day,
night temperature
Day: 19/21 °C
Night: 16 °C
Day: 21 °C
Night: 17 °C
13
(operating
instructions)
Control method
Room flow/room
output can be
changed over.
Room flow is the
default setting and
can only
be switched over
at the customer
service level.
If room output is to
be used, contact
your Buderus
customer service.
–
Self-test
Self-test available
and can be
activated.
Permanent self-
test in the
background - no
activation
required.
The RC35
programming unit
tests the system
continually If a fault
is found, the RC35
programming unit
automatically gives a
fault display.
–
Room
temperature hook-
up (control type)
HS = 3 K
HS = 0 K
36
Table 4
Differences between ERC and RC35