Installation
Logamatic EMS – 6 720 801 387 (2011/05)
12
3
3.1.2 Installation on boiler
Installation directly on the boiler is possible where the boiler is equipped with the Energy
Management System (EMS).
The outside temperature sensor for weather-compensated control is not delivered as standard, but
can be ordered as an accessory.
3.2
Types of installation
The programming unit can be installed in three different ways:
• As the only programming unit in the system (basic setting): the programming unit is installed in a
living room (reference room) or on the boiler
1)
.
Example: single family house with one heating circuit.
• As the only programming unit in a heating system with two or more heating circuits
2)
(
Æ
fig. 2, [1]).
Examples: underfloor heating on one storey, radiators in the others, or a home combined with a
separate dwelling unit or with a medical practice room.
• In association with a remote programmer (e.g.RC2x, RC20/RF, fig. 2, [2]) In this case there are
always two separate heating circuits. Remote control units cannot be used for boilers with
UBA1.x.
Examples: underfloor heating on one floor, radiators on the others; or a main flat together with a
separate granny flat or doctor's surgery.
If a HM10 hybrid module is used, the installation must be carried out with the wall
bracket. If it is installed on the boiler, it does not function correctly.
1) Not possible if the HM10 hybrid module is used
2) Not possible with boilers with UBA1.x and DBA.