Control Panel
Access | en
235
Bosch Security Systems, Inc.
Program Entry Guide
2017.03 | 09 | F.01U.303.998
For a D9210C or B901 on the SDI bus (Door Source = SDI) shorting the tamper input (T+) to
common (COM) creates a Point Missing event for the Door Point, page 228.
For a B901 on the SDI2 bus (Door Source = SDI) shorting the tamper input (T+) to common
(COM) creates a Point Missing event for the Door Point, page 228 and a Tamper event for the
B901 module.
RPS Menu Location
Access > Doors > Enclosure Tamper
See also
–
Door Point, page 228
12.2
Global Access settings
12.2.1
Card Type
Default
: 26 bit
Selections
:
26 bit
37 bit no site code
37 bit with site code
This parameter specifies the card or token format used for all of the door controllers and
keypads.
Notice!
Set to 26 bit when credentials (card or token) are used with a B942.
Default
Site Code, page 147
for card types
26 bit: default site code is 255.
37 bit no site code: default site code is blank. The site code is not configurable (Site Code
parameter is grayed out).
37 bit with site code: default site code is 65535.
RPS Menu Location
Access > Global Keypad Settings > Card Type