158
en | User Configuration
Control Panel
2017.03 | 09 | F.01U.303.998
Program Entry Guide
Bosch Security Systems, Inc.
–
Passcode (P) - Require a passcode to enable this function panel wide.
This function allows local keypad programming for a select list of parameters from keypads.
The Installer passcode is the only passcode that provides access to keypad programming.
If at least one area is armed or the control panel is communicating with RPS, you cannot
access keypad programming.
RPS Menu Location
User Configuration > User Keypad Functions > Keypad Programming
Further information
Refer to the control panel documentation for more information on keypad programming.
9.4
Authority Levels
9.4.1
Authority Level Name
Default
: L1 (to L15)
Selections
: Enter up to 32 characters.
This parameter allows the user to enter a description for an authority level. Enter up to 32
characters from the Latin-1 8-bit (ISO/IEC 8859-1) character set to describe the area.
Note: First and Second languages are programmed during panel account setup in the Panel
Data window. Supported languages include English, Spanish, French and Portuguese.
RPS Menu Location
User Configuration > Authority Levels > Authority Level Name
9.4.2
Authority Level Name (Second Language)
Default
: L1 (to L15)
Selections
: Enter up to 32 characters.
This parameter allows the user to enter a description for an authority level. Enter up to 32
characters from the Latin-1 8-bit (ISO/IEC 8859-1) character set to describe the area.
Note: First and Second languages are programmed during panel account setup in the Panel
Data window. Supported languages include English, Spanish, French and Portuguese.
RPS Menu Location
User Configuration > Authority Levels > Authority Level Name (second language)
9.4.3
Disarm Select
Default:
Authority Levels 1-5, 14: Enabled (E)
Authority Levels 6-13, 15: Blank (-)
Selections:
–
Blank (-): This function is not authorized for the user who is assigned this authority level.
–
Enabled (E): This function is authorized for the user who is assigned this authority level.
The parameter disarms areas that are All On or Part On.
If enabled, the following disarming choices are available to the user with this authority.
–
Disarm All: Disarms all areas within the scope of the keypad being used by accessing the
function menu and the Authority Level of the user performing the function.
–
Disarm Area#: Disarms only the area that is displayed.
The options available for arming and disarming are dependent upon Area Type and Scope.
Configure the Duress Enable parameter to Yes in applicable areas, or the keypad will respond