Control Panel
Schedules | en
207
Bosch Security Systems, Inc.
Program Entry Guide
2017.03 | 09 | F.01U.303.998
11
Schedules
11.1
Open/Close Windows
Use these windows to set a schedule for disarming and arming. The disarming and arming
schedules provide several independent features:
–
Suppress normal opening and/or closing reports when Disable O/C in Window, page 103 is
set to Yes.
–
Generate a FAIL TO OPEN report if the area is not disarmed on schedule when Fail to
Open, page 104 is set to Yes.
–
Provide a warning tone and [PLEASE CLOSE NOW] display at the keypad when it is time
to arm the area.
–
Generate a FAIL TO CLOSE report if the area is not armed on schedule when Fail to Close,
page 104 is set to Yes.
–
Automatically arm the area at the end of the closing window when Auto Close, page 104 is
set to Yes.
Opening and closing schedules can be set up independently. For example, if you only want to
use features provided by closing windows, leave times blank in the opening windows
parameters and program closing window times.
11.1.1
Opening window timeline
Example using two opening windows on the same day
Areas that are disarmed between midnight and 6 AM generate Opening reports.
Areas that are disarmed between 6 AM and 7 AM generate Early to Open reports.
If the area is disarmed between 7 AM and 8 AM regular Opening Reports are generated.
If Disable O/C in Window is programmed as "yes" the Opening Report is not transmitted to the
central station.
If the area is not disarmed by 8:01 AM then a Fail to Open event is generated if Fail to Open is
programmed as "yes" in Opening and Closing Options.
If the user disarms the area between 8:01 AM and 12:59 PM then a Late to Open event is
generated.
Areas that are disarmed between 1 PM and 2 PM generate Early to Open reports.
If the area is disarmed between 2 PM and 3 PM regular Opening Reports are generated.
If Disable O/C in Window is programmed as "yes" the Opening Report is not transmitted to the
central station.
If the area is not disarmed by 3:01 PM then a Fail to Open event is generated if Fail to Open is
programmed as "yes" in Opening and Closing Options.
If the user disarms the area between 3:01 PM and 11:59 PM then a Late to Open event is
generated.