This parameter sets the IP address for the network access point. Enter up to 99 alphanumeric
characters. The field is case sensitive.
RPS menu location
SDI2 modules > IP Communicator > B450 Cellular > Network access point name (APN)
14.5.9
Network Access Point User Name
Notice!
Important configuration information for cellular communication
Refer to Configuring for Cellular Service, page 280 for an overview and configuration
information.
Default
: Blank
Selections
: 0-30 ASCII characters
This parameter specifies the user name for the Network Access Point.
Enter up to 30 alphanumeric characters. The field is case sensitive.
RPS menu location
SDI2 modules > IP Communicator > B450 Cellular > Network access point user name
14.5.10
Network Access Point Password
Notice!
Important configuration information for cellular communication
Refer to Configuring for Cellular Service, page 280 for an overview and configuration
information.
Default
: Blank
Selections
: 0-30 ASCII characters
This parameter sets the password required to access the Network Access Point.
Enter up to 30 alpha-numeric characters. The password is case sensitive.
RPS menu location
SDI2 modules > IP Communicator > B450 Cellular > Network access point password
14.6
B520 aux power supply
The B520 Auxiliary Power Supply is a device that attaches to the SDI2 bus of the control
panel. It provides a supervised 12 Volt DC 2.5 Amp auxiliary power supply.
Each power supply might support 2 separate 12V nominal lead acid batteries with a capacity
of 7-18 Ah.
Panel type
Modules supported
B9512G
8
B8512G
4
Tab. 14.4:
Capacity