Audio, Alarms and Relay Connections
Alarm Input
All AutoDome Junior models provide connections for two alarm inputs, one alarm output, and
one audio input. Each alarm input can be activated by dry contact devices such as pressure
pads, passive infrared detectors, door contacts, and similar devices.
ALARM OUT
ALARM IN 1
ALARM IN 2
GR
OUND
A
UDIO GND
A
UDIO IN
WHT
BRN
OR
G
GRN
YEL
BL
U
Figure 9.1: Six-wire Audio and Alarm In/Out Cable
Wire Color
Function
White
Alarm Out
Brown
Alarm In 1
Orange
Alarm In 2
Green
Ground
Yellow
Audio In
Blue
Audio Ground
The table below summarizes the size and distance wires.
Wire Size
Maximum Distance
AWG
mm
feet
meters
22
0.644
500
152.4
18
1.024
800
243.8
Table 9.1: Alarm Wire Guide
You wire alarms either Normally Open (N.O.) or Normally Closed (N.C.), and must program the
alarm inputs N.O. (the default) or N.C. through the AutoDome Junior main menu.
Connecting Alarms (inputs 1 through 2)
You can configure alarms 1 through 2 as Normally Open (N.O.) or Normally Closed (N.C.)
alarms.
Connecting a Normally Open Alarm
4
Connect the alarm to the appropriate input (1 through 2) and ground at the AutoDome
Junior.
9
9.1
9.2
9.2.1
42
en | Audio, Alarms and Relay Connections
AutoDome Junior HD Series
2014.11 | 6.1 | F.01U.275.803
Operation Manual
Bosch Security Systems, Inc.
Содержание AutoDome Junior HD VJR Series
Страница 1: ...AutoDome Junior HD Series VJR Series en Operation Manual ...
Страница 2: ......
Страница 112: ......
Страница 113: ......