SNMP
The camea supports the SNMP V2 (Simple Network Management Protocol) for managing and
monitoring network components, and can send SNMP messages (traps) to IP addresses. The
unit supports SNMP MIB II in the unified code. If you wish to send SNMP traps, enter the IP
addresses of one or two required target devices here.
If you select On for the SNMP parameter and do not enter an SNMP host address, the camera
does not send them automatically, but only replies to SNMP requests. If you enter one or two
SNMP host addresses, SNMP traps are sent automatically. Select Off to deactivate the SNMP
function.
1. SNMP host address / 2. SNMP host address
If you wish to send SNMP traps automatically, enter the IP addresses of one or two required
target units here.
SNMP traps
You can select which traps are to be sent.
1.
Click Select. A list is opened.
2.
Click the checkboxes to select the required traps. All the checked traps will be sent.
3.
Click Set to accept the selection.
Authentication
If a RADIUS server is employed in the network for managing access rights, authentication must
be activated here to allow communication with the unit. The RADIUS server must also contain
the corresponding data.
To configure the unit, you must connect the camera directly to a computer using a network
cable. This is because communication via the network is not enabled until the Identity and
Password parameters have been set and successfully authenticated.
Identity
Enter the name that the RADIUS server is to use for identifying the camera.
Password
Enter the password that is stored in the RADIUS server.
RTSP port
If necessary, select a different port for the exchange of the RTSP data from the list. The
standard RTSP port is 554. Select Off to deactivate the RTSP function.
UPnP
You can activate the universal plug and play function (UPnP). When activated the camera
reacts on requests from the network and will be registered automatically as a new network
device on the inquiring computers. The access to the camera is then possible via the Windows
file explorer, and without knowledge of the camera’s IP address.
Notice!
In order to use the UPnP function on a computer with Windows XP or Windows Vista, the
Universal Plug and Play Device Host and the SSDP Discovery services must be activated.
This function should not be used in large installations due to the large number of registration
notifications.
TCP Metadata Input
The device can receive data from an external TCP sender, for example an ATM or POS device,
and store it as metadata. Select the port for TCP communication. Select Off to deactivate the
TCP metadata function.
Sender IP Address
Enter the IP address of the TCP metadata sender here.
96
en | Configuring the AutoDome Junior HD