P aram eter s
4
User instructions. DGM speed regulator
115
4,036 / 4,066
AIx wire breakage time
Unit:
Relation with
the parameter:
Parameter
manual:
P. xy
Acquisition status:
2
min.:
0
value (enter!)
max.:
32767
Def.:
0.5
After connections to the network, wire breakage recognition is activated
only after the set time
4,037 / 4,067
AIx inversion
Unit: whole
Relation with
the parameter:
Parameter
manual:
P. xy
Acquisition status:
2
min.:
0
value (enter!)
max.:
1
Def.:
0
Here it is possible to invert the analog input signal.
0 = inactive (example: 0 V = 0 %
10 V = 100 %)
1 = active (example: 0 V = 100 %
10 V = 0 %)
5.3.6
Digital inputs
from 4.110 to
4.113
DIx inversion
Unit: whole
Relation with
the parameter:
Parameter
manual:
P. xy
Acquisition status:
2
min.:
0
value (enter!)
max.:
1
Def.:
0
With this parameter, it is possible invert the digital input.
0 = inactive
1 = active