I nstal l ati on
User instructions. DGM speed regulator
74
Fig. 30: Motor connection size D
14. Lead the connection cable to the motor (14) through the cable gland (15) [M40] in the
speed regulator (9).
IMPORTANT INFORMATION
The cable gland is used to lighten the traction; the PE connection cable must be connected
in advance (significantly longer)!
15. Connect the cables in the connection terminal boards [X4] (16) as follows:
Terminal no.
Name
Assignment
1
PE
Protective conductor
2
U
Motor phase 1
3
V
Motor phase 2
4
W
Motor phase 3
Table 16: Motor connection assignment X4