P aram eter s
4
User instructions. DGM speed regulator
104
5.3.2
Fixed frequency
This mode must be selected with parameter 1.100; see also the selection of the operating
mode.
2,050
Fixed frequency mode
Unit: whole
Relation with
the parameter:
1,100
from 2.051 to
2.057
Parameter
manual:
P. xy
Acquisition status:
2
min.:
0
value (enter!)
max.:
4
Def.:
2
Selection of the digital inputs used for the fixed frequencies
0 = Digital In 1
1 = Digital In 1, 2
2 = Digital In 1, 2, 3
(Fixed frequency 1) (2.051)
(Fixed frequency 1 - 3) (from 2.051 to 2.053)
(Fixed frequency 1 - 7) (from 2.051 to 2.057)
3 = Foil keypad (key I = fixed frequency 1 / key II = fixed frequency 2)
4 = Integrated foil keypad (key I = fixed frequency 1 / key II = fixed frequency
2)
from 2.051 to
2.057
Fixed frequency
Unit: Hz
Relation with
the parameter:
1,020
1,021
1,100
1,150
2,050
Parameter
manual:
P. xy
Acquisition status:
2
min.:
- 400
value (enter!)
max.:
+ 400
Def.:
0
Frequencies that must be set based on the connection model for digital inputs
1
– 3 set in parameter 2.050.
See the chapter Explanation of the operating modes/fixed frequency.