P aram eter s
4
User instructions. DGM speed regulator
105
5.3.3
Motor potentiometer function
This operating mode must be selected in parameter 1.130.
The function can be used as a reference value source for the frequency mode and for the PID
process regulator.
Via the motor potentiometer, it is possible to increase and reduce the reference value
(PID/frequency) in increments. For this purpose, use parameters 2.150 to 2.154.
2,150
MOP digital input
Unit: whole
Relation with
the parameter:
1,130
4,030
4,050
Parameter
manual:
P. xy
Acquisition status:
2
min.:
0
value (enter!)
max.:
8
Def.:
3
Selection of the source for increasing and reducing the reference value
0 = Digital input 1 + / digital input 2 -
1 = Digital input 1 + / digital input 3 -
2 = Digital input 1 + / digital input 4 -
3 = Digital input 2 + / digital input 3 -
4 = Digital input 2 + / digital input 4 -
5 = Digital input 3 + / digital input 4 -
6 = Analog input 1 + / analog input 2 - (must be selected in
parameter 4.030 / 4.050)
7 = DGM Soft- PLC
8 = Foil keypad (key I - / key II +)
2,151
MOP pitch amplitude
Unit: %
Relation with
the parameter:
1,020
1,021
Parameter
manual:
P. xy
Acquisition
status:
2
min.:
0
value (enter!)
max.:
100
Def.:
1
Interval, based on which the reference value must be modified each time the
key is pressed.