I nstal l ati on
User instructions. DGM speed regulator
53
3.4.5
Brake chopper connections
Terminal no.
Name
Assignment
1
B +
Brake chopper connection (+)
2
B -
Brake chopper connection (-)
Table 10 Assignment of the optional brake chopper terminals
3.4.6
Control connections X5, X6, X7
Control connec ti ons for th e stand ard appl i cati on boa rd
Fig. 16: Control connections for the standard application board