The parameters are stored in the frequency inverter in various languages. The parameter description
is displayed by the PC control software (e.g. VPlus) in the selected
Language
33
.
Language 33
Function
0 - Deutsch
Parameter description in German
1 - English
Parameter description in English
2 - Italiano
Parameter description in Italian
100 -
The Language is set via VPlus (ACU Firmware as from 5.2.0)
Up to ACU Firmware 5.1.11, the language is set via
Language
33
= 0,1,2, as from
ACU Firmware Version 5.2.0, the parameter texts are managed by the VPlus PC
software. If
Language
33
is set to 100, settings 0,1 and 2 are disabled.
As from Firmware Version 5.2.0, you will need a suitable VPlus Version (VPlus 7.38 or
higher).
10.9
Programming
Parameter
Program
34
enables acknowledgment of a error signal and resetting to the factory
settings. The display of the control unit reads "dEFLt" or "rESEt" and the LEDs indicate the status of
the frequency inverter.
Program 34
Function
111 - Parameter transfer
Control unit P 500 is prepared for parameter transmission. A connected
frequency inverter can receive data from the control unit.
110 - Standard
operation
Resetting of control unit KP 500 to standard operation mode.
123 - Reset
The current error message can be acknowledged via digital input
S1IND/STOA or the software parameter. The display of the control unit
reads "rESEt".
4444 - Default
The parameters of the selected configuration, except for a few
exceptions, are reset to the default settings. The display of the control
unit reads "dEFLt".
Parameters
Control Level
28
and
Configuration
30
are not changed when reset to
default setting
(Program
34
= 4444).