12/16
Operating Instructions ACU
115
10
Inverter data
The series ACU frequency inverters are suited for a wide range of applications. The modular
hardware and software structure enables customer-specific adaptation. The available hardware
functionality of the frequency inverter is displayed in the control unit and the optional control
software VPlus. The software parameters can be adjusted to meet the requirements of the specific
application.
10.1
Serial Number
Serial Number
0
:
603409000 ; 06053980 (part no.; serial no.)
Rating plate:
Type: ACU 401 – 09 ; Serial No.: 06053980
10.2
Optional Modules
Modular extension of the hardware is possible via the plug-in slots. The
Optional Modules
1
detected by the frequency inverter and the corresponding designations are displayed on the control
unit and in the optional control software VPlus after initialization. For the parameters required for the
extension module, refer to the corresponding operating instructions.
CM-232 ; EM-IO-01
10.3
Inverter Software Version
The firmware stored in the frequency inverter defines the available parameters and functions of the
software. The software version is indicated in parameter
Inverter Software Version
12
. In addition
to the version, the 6-digit software key is printed on the rating plate of the frequency inverter.
Inverter Software Version
12
: 5.4.0
Rating plate :
Version: 5.4.0 ; Software: 15 000 190
Copyright
15
(C) 2013 BONFIGLIOLI VECTRON
10.4
Set Password
As a protection against unauthorized access, parameter
Set Password
27
can be set such that
anyone who wants to change parameters must enter this password this password before. A change
of parameter is only possible if the password in entered correctly. If parameter
Set Password
27
is
set to zero, no password is required for access to the parameters. The previous password is deleted.
Parameter
Setting
No.
Description
Min.
Max.
Factory setting
27 Set Password
0
999
0
10.5
Control Level
The
Control Level
28
defines the scope of the functions to be parameterized. The operating
instructions describe the parameters on the third control level. These parameters should only be set
by qualified users.
Parameter
Setting
No.
Description
Min.
Max.
Factory setting
28 Control Level
1
3
1
10.6
User Name
The
User Name
29
can be entered via the optional control software VPlus. ???
32 alphanumeric characters