14.4 BOCAMODEMcard-PC
52
S7
Wait for Carrier/Dial tone: (60)
S7 specifies the amount of time that the modem waits to detect the
remote modem carrier aver dialing the telephone number. If the remote
modem carrier is not detected within the So time limit, the modem will
hang-up and send a NO CARRIER response code to the DTE. If the
remote modem carrier is detected, the modem goes into On-line Data
Mode and sends a CONNECT message to the DTE. S7 also specifies
the time duration for the ‘W’ (walt for dial tone) dial modifier. Range: 1-
255 seconds
S8
Pause Time for Dial Modifier: (2)
S8 specifies the amount of time that the modem will pause during the
dialing process each time the ‘,’ dial modifier is detected in the dialing
string.
Range: 0-255 seconds
Default: 2 seconds
S9
Carrier Detect Response Time: (6)
S9 specifies how long the remote modem carrier must be present on the
telephone line before the modem will detect it and turns on DCD. The
greater the time duration, the less likely that a false carrier detection will
occur due to noise on the telephone line.
Range: 1-255 (10ths second)
Default: 6 (10ths seconds)
S10
Lost Carrier Hang Up Delay: (14)
S10 specifies amount of time the modem waits before hanging up after
the loss of the remote modems carrier. This delay allows for the
temporary loss of remote modem carrier without causing the local
modem to hang up. When set to 255, the modem will not disconnect
upon loss of remote modem carrier.
Range: 1-255 (10ths second)
Default: 14 (10ths second)