I01�High-voltage�Components
2.�Important�Notes
9
Removing�the�connector�of�the�high-voltage
cable
The�connector�of�the�high-voltage�cable�must
now�be�removed�in�the�direction�of�the�arrow.
After�the�connector�has�been�pulled�out�a
few�millimeters�(A),�one�encounters�a�higher
counterforce.�The�connector�must�then�be
pulled�out�further�in�the�same�direction (B).
Under�no�circumstances�must�the�connector
be�pressed�back�into�the�socket�on�the�high-
voltage�component�after�reaching�position�(A).
This�may�damage�the�connector�on�the�high-
voltage�components.
The�high-voltage�connector�of�the�high-voltage
cables�must�be�pulled�out�at�a�right�angle�in�two
steps�and�in�the�same�direction.�Changing�the
direction�of�movement�during�removal�is�not
permitted.
Proceed�in�the�reverse�order�when�reattaching�the�high-voltage�cable.�The�following�graphic�shows
the�complex�design�of�the�high-voltage�connector�on�the�high-voltage�components�and�explains�why
one�must�proceed�with�care�when�removing�and�inserting�high-voltage�cables.
High-voltage�connector�on�the�high-voltage�component