I01�High-voltage�Components
2.�Important�Notes
11
The�connector�of�the�high-voltage�cable�(1)�is
located�at�the�high-voltage�connection�of�the
component�(2)�and�is�locked.
The�two�locking�elements�(2)�must�be�pressed
together�in�the�direction�of�arrow�(1).�The
mechanical�lock�of�the�connector�at�the
connection�of�the�high-voltage�component�is
thus�removed.
While�the�locking�elements�are�further�pushed
together,�the�connector�must�be�removed
lengthways�in�the�direction�of�arrow�(1).
When�reconnecting�the�high-voltage�cable�the�locking�elements�must�not�be�pushed�together.�It�is
sufficient�to�slide�the�connector�lengthways�onto�the�high-voltage�connection�of�the�component.
Ensure�that�the�locking�elements�engage�("clicking"�noise).�In�addition,�the�engaging�of�the�locking
elements�should�be�checked�by�subsequent�pulling�on�the�connector.
Содержание I01
Страница 1: ...Technical training Product information BMW Service I01 High voltage Components...
Страница 49: ...I01 High voltage Components 3 Electric Motor 43 System wiring diagram for the drive control...
Страница 178: ...I01 High voltage Components 12 Technical Safety Precautions 172 Main wiring diagram for high voltage interlock loop...
Страница 189: ......
Страница 190: ...Bayerische Motorenwerke Aktiengesellschaft Qualifizierung und Training R ntgenstra e 7 85716 Unterschlei heim Germany...