I01�High-voltage�Components
5.�High-voltage�Battery�Unit
80
Connections�of�the�high-voltage�battery�unit,�left
Index
Explanation
1
Vent�hole
2
High-voltage�interlock�loop�connector/bridge
3
Mechanical�slide
4
Separate�contact�for�high-voltage�cable
5
Contact�for�shielding
6
Contact�protection
A�contact�is�available�for�shielding�around�each�of�the�two�electrical�contacts�for�the�high-voltage
cables.�The�shielding�of�the�high-voltage�cable�(shielding�for�each�cable)�is�continued�into�the�housing
of�the�high-voltage�battery�unit�and�thus�contributes�to�the�electromagnetic�compatibility�(EMC).
In�addition,�the�high-voltage�connection�provides�protection�against�contact�with�live�parts.�The
actual�contacts�are�coated�in�plastic�so�that�nobody�can�touch�them�directly.�Only�when�the�cable�is
connected�is�the�coating�pushed�away�and�the�contact�established.�The�plastic�slide�serves�as�the
mechanical�latch�mechanism�of�the�connector.�In�addition,�it�is�also�an�element�of�a�safety�function:�If
the�high-voltage�cable�is�not�connected,�the�slide�conceals�the�connection�for�the�bridge�of�the�high-
voltage�interlock�loop.�Only�when�the�high-voltage�cable�is�properly�connected�and�the�connector
is�locked,�is�this�connection�accessible�and�the�bridge�can�be�inserted.�This�guarantees�that�only
when�a�high-voltage�cable�is�connected�is�the�circuit�of�the�high-voltage�interlock�loop�also�closed.
This�principle�applies�to�all�high-voltage�connections�in�the�I01,�for�instance�connections�at�the�high-
voltage�battery�unit,�at�the�electrical�machine�electronics,�at�the�convenience�charging�electronics
and�at�the�range�extender�electrical�machine�electronics.�The�high-voltage�system�can�only�be�active
when�all�high-voltage�cables�are�connected.�This�is�additional�protection�against�contact�with�contact
surfaces,�which�otherwise�may�carry�voltage.
Содержание I01
Страница 1: ...Technical training Product information BMW Service I01 High voltage Components...
Страница 49: ...I01 High voltage Components 3 Electric Motor 43 System wiring diagram for the drive control...
Страница 178: ...I01 High voltage Components 12 Technical Safety Precautions 172 Main wiring diagram for high voltage interlock loop...
Страница 189: ......
Страница 190: ...Bayerische Motorenwerke Aktiengesellschaft Qualifizierung und Training R ntgenstra e 7 85716 Unterschlei heim Germany...