I01�High-voltage�Components
2.�Important�Notes
5
In�order�to�be�able�to�separate�the�connector,
the�mechanical�lock�(1)�has�to�be�pressed.
As�soon�as�the�mechanical�lock�has�been
removed,�the�connector�can�be�pulled�from�the
socket�a�few�millimeters.
Do�not�pull�any�further�or�harder�if�resistance
can�be�felt.�The�high-voltage�safety�connector
cannot�be�disconnected�from�each�other
completely.
When�the�high-voltage�safety�connector�is
pulled�out�far�enough�the�message�"OFF"�is
visible.�The�high-voltage�system�is�thus�in�a�de-
energized�state.
2.2.3.�Provide�the�high-voltage�system�with�a�safeguard�against�unintentional
restarting
Securing�against�restart�is�also�effected�at�the�high-voltage�safety�connector.�A�commercially�available
U-lock�(for�example,�ABUS 45/40)�is�required�for�this�purpose.