
BLUEBOX CX Industrial UHF
Page 87 of 126
7.3
Power Supply and CAN Bus Connection (a2)
5-poles M12 A-coded male connector
Pin
No
Min
Typical
Max
Description
PE
1
Protected Earth
+ PWR
2
10Vdc
12/24Vdc
36Vdc
DC power supply
- PWR
3
DC power supply return path
CAN H
4
CAN bus connection (CAN H)
CAN L
5
CAN connection (CAN L)
To ensure interference-free operation, the device must be
connected to an earth potential free from external voltage.
Hereinafter a cross reference table between connection pin number and the color
of the wires of a standard open ended cable.
Pin
No
Wire Cable Color
PE
1
Brown
+ PWR
2
White
- PWR
3
Blue
CAN H
4
Black
CAN L
5
Grey
The shield of the cable should be left unconnected.
Содержание IDTRONIC CX Industrial UHF
Страница 1: ...BLUEBOX CX Industrial UHF Page 1 of 126 UHF RFID System BLUEBOX CX Industrial UHF...
Страница 80: ...BLUEBOX CX Industrial UHF Page 80 of 126 7 1 2 Wiring 5326U opt1 rrr 7 1 3 Wiring 5327U rrr a1 b c1 a1 b d...
Страница 105: ...BLUEBOX CX Industrial UHF Page 105 of 126 13 13 Mechanical Drawings 5348U opt1 rrr All the dimensions are in mm...
Страница 122: ...BLUEBOX CX Industrial UHF Page 122 of 126 5 On the next screen choose Advanced Options...
Страница 123: ...BLUEBOX CX Industrial UHF Page 123 of 126 6 Then click on Startup Settings...
Страница 126: ...BLUEBOX CX Industrial UHF Page 126 of 126...