BLUEBOX CX Industrial UHF
Page 51 of 126
1
2
3
4
5
6
7
Input1
Mode
Input2
Mode
Extension
Time
Gate Time
Debounce
Time
Output 1
Time
0x00
0x01
0x00
0x00
0x00
0x00
0x00
0x00
Where:
Parameter
Description
Input1 Mode
Input 1 activation / deactivation mo
de of the ‘continuous’ mode in ‘trigger’ mode:
•
0x00: Disabled;
•
0x01: ON -> Activate antennas; OFF -> Deactivate antennas;
•
0x02: OFF -> Activate antennas; ON -> Deactivate antennas;
•
0x03: ON -> Activate antenna 1; OFF -> Deactivate antenna 1;
•
0x04: OFF -> Activate antenna 1; ON -> Deactivate antenna 1;
•
0x05: ON -> Activate antenna 2; OFF -> Deactivate antenna 2;
•
0x06: OFF -> Activate antenna 2; ON -> Deactivate antenna 2.
Input2 Mode
Input 2 activation / deactivation mode of the ‘continuous’ mode in ‘trigger’ mode:
•
0x00: Disabled;
•
0x01: ON -> Activate antennas; OFF -> Deactivate antennas;
•
0x02: OFF -> Activate antennas; ON -> Deactivate antennas;
•
0x03: ON -> Activate antenna 1; OFF -> Deactivate antenna 1;
•
0x04: OFF -> Activate antenna 1; ON -> Deactivate antenna 1;
•
0x05: ON -> Activate antenna 2; OFF -> Deactivate antenna 2;
•
0x06: OFF -> Activate antenna 2; ON -> Deactivate antenna 2.
Extension
Time
‘Continuous’ mode activation management with inputs extension time.
•
In ‘trigger’ mode, if =0 the trigger is
level sensitive, otherwise it is edge
sensitive and this time defines the ‘continuous’ mode activation time extension
after the input change.
•
In ‘gate’ mode it defines the ‘continuous’ mode activation time extension after
the crossing of the gate.
And the values allowed are:
•
Decimal 0 … 99 for time in seconds (0 … 99 seconds);
•
Decimal 100 … 199 for time in minutes (0 … 99 minutes).
Gate Time
The maximum gate crossing time. If =0 the ‘gate’ mode is disabled, otherwise it is the
maximum gate crossing time:
•
Decimal 0 … 99 for time in seconds (0 … 99 seconds);
•
Decimal 100 … 199 for time in minutes (0 … 99 minutes).
Debounce
Time
The inputs anti-bounce time. 0 setting is internally overwritten with 50ms.
•
Decimal 0 … 99 for time in mseconds (0 … 990 m
seconds)
•
Decimal 100 … 199 for time in seconds (0.0 … 9.9 seconds)
Output 1 Time
Output 1 activation time with output 1 activation on tag presence / new tag event
enabled. If =0 the output 1 is continuously activated with the tag presence, otherwise
is activated with a new tag event for a time defined by this parameter.
Содержание IDTRONIC CX Industrial UHF
Страница 1: ...BLUEBOX CX Industrial UHF Page 1 of 126 UHF RFID System BLUEBOX CX Industrial UHF...
Страница 80: ...BLUEBOX CX Industrial UHF Page 80 of 126 7 1 2 Wiring 5326U opt1 rrr 7 1 3 Wiring 5327U rrr a1 b c1 a1 b d...
Страница 105: ...BLUEBOX CX Industrial UHF Page 105 of 126 13 13 Mechanical Drawings 5348U opt1 rrr All the dimensions are in mm...
Страница 122: ...BLUEBOX CX Industrial UHF Page 122 of 126 5 On the next screen choose Advanced Options...
Страница 123: ...BLUEBOX CX Industrial UHF Page 123 of 126 6 Then click on Startup Settings...
Страница 126: ...BLUEBOX CX Industrial UHF Page 126 of 126...