o
antenna
: the detection antenna info
(optional variable present
only if the reading antenna information flag in the general
parameters is active)
:
▪
0x01 -> Antenna 1.
▪
0x02 -> Antenna 2
o
direction
: the gate crossing direction
(optional variable present
only if ‘gate’ mode is active)
:
▪
0x01 -> Crossing from input 1 to input 2.
▪
0x02 -> Crossing from input 2 to input 1.
o
timestamp
: the detection timestamp. BCD coded with the following
format yyyyMMddhhmmss. In case of no RTC or RTC error this field
is filled with 0xFF bytes.
The connection has an inactivity timeout of 120 seconds. The auto connection
start event could be:
•
Buffer mode: starts the auto connection when the set number of records
is reached in the records database.
•
Time mode: starts the auto connection on the timeout of the connection
interval time if the records database contains one or more records.
•
time mode: hybrid mode, start the auto connection when the set
number of records is reached in the records database or on the timeout fo
the connection interval time if the records database contains one or more
records.
Two subsets of the ‘continuous’ mode
are also defined:
•
‘Trigger’ mode: the activation and deactivation of the ‘continuous’ mode is
triggered with inputs. The trigger could be level sensitive or edge sensitive
depending on the
‘extension time’ setting (to be set in a range of 0 … 99
seconds or 0 ... 99 minutes, default value 0 seconds).
•
‘Gate’ mode:
the activation
of the ‘continuous’ mode is triggered with the
activation of an input. The deac
tivation of the ‘continuous’ mode is
triggered with the activation of the other input but, the activation of the
‘continuous’ mode could also be extended with the ‘extension time’ (to be
set in a range of 0 … 99 seconds or 0 ... 99 minutes, default value 0
seconds). The crossing of the gate is managed with a maximum crossing
‘gate time’ (to be set in a range of 0 … 99 seconds or 0 ... 99 minutes,
default value 0 seconds) which de
activates the ‘continuous’ mode in case
of no successful crossing of the gate within this time. Only with a
successful crossing of the gate data (tag ID and gate crossing direction
Содержание IDTRONIC CX Industrial UHF
Страница 1: ...BLUEBOX CX Industrial UHF Page 1 of 126 UHF RFID System BLUEBOX CX Industrial UHF...
Страница 80: ...BLUEBOX CX Industrial UHF Page 80 of 126 7 1 2 Wiring 5326U opt1 rrr 7 1 3 Wiring 5327U rrr a1 b c1 a1 b d...
Страница 105: ...BLUEBOX CX Industrial UHF Page 105 of 126 13 13 Mechanical Drawings 5348U opt1 rrr All the dimensions are in mm...
Страница 122: ...BLUEBOX CX Industrial UHF Page 122 of 126 5 On the next screen choose Advanced Options...
Страница 123: ...BLUEBOX CX Industrial UHF Page 123 of 126 6 Then click on Startup Settings...
Страница 126: ...BLUEBOX CX Industrial UHF Page 126 of 126...