BLUEBOX CX Industrial UHF
Page 88 of 126
7.4
Power Supply Connection (a3)
5-poles M12 A-coded male connector
Pin
No
Min
Typical
Max
Description
+ PWR
1
10Vdc
12/24Vdc
36Vdc
DC power supply
NC
2
Not connected
- PWR
3
DC power supply return path
NC
4
Not connected
PE
5
Protected Earth
To ensure interference-free operation, the device must be
connected to an earth potential free from external voltage.
Hereinafter a cross reference table between connection pin number and the color
of the wires of a standard open ended cable.
Pin
No
Wire Cable Color
+ PWR
1
Brown
NC
2
White
- PWR
3
Blue
NC
4
Black
PE
5
Grey
The shield of the cable should be left unconnected.