BLUEBOX CX Industrial UHF
Page 34 of 126
BLUEBOX
will hold onto a maximum of 10 tags when configured
to use the ‘spontaneous’ message.
Once the 10 tag limit is reached,
the new tags will be discarded!
In ‘continuous’ mode the
BLUEBOX
can be configured to automatically connect
to a data acquiring TCP server (optionally with HTTP POST messages).
•
If configured and available an host can wait for an incoming TCP
connection. On a succesful connection there is a fixed inactivity timeout of
120 seconds, the
BLUEBOX
first sends its serial number and then waits
for incoming commands:
SOH <add h> <add l> STX <sn 1 h> <sn 1 l> ... <sn i h> <sn i l>
… <sn 6 h> <sn 6 l> ETX <bcc> CR
Where <sn 1 h> <
sn 1 l> … <sn 6 h> <sn 6 l> is the serial number of the
device, it is a numeric code constituted by 12 digits, the bytes of the SN
are BCD-coded and so every byte encodes 2 digits (see the protocol
manual for details).
•
If configured and available an host can wait for incoming HTTP POST to
receive records messages. An ACK/NAK reply is implemented through the
reception of the HTTP status OK message and in case of success the record
is dequed from the reacords database. On a succesful connection there is
a fixed inactivity timeout of 120 seconds.
These are the POST variables sent by
BLUEBOX
:
o
reader_sn
: the
BLUEBOX
serial number.
o
mac_address
: the
BLUEBOX
MAC address.
o
ip_address
: the
BLUEBOX
IP address.
o
tag_type
: the transponder type
(optional variable present only if
the tag type information flag in the general parameters is active)
:
▪
0x02: ISO 18000-63
29
(EPC Class-1 Gen-2).
o
tag_id
:
ID of the tag (see tag’s ID specifications).
o
rssi
: The detection
tag’s signal RSSI I and Q measured values in dB
(optional variable present only if the RSSI information flag in
the RF parameters is active).
29
ISO 18000-6C became ISO 18000-63 in 2012 due to ISO naming rules that do not allow letters in standards names.
Содержание IDTRONIC CX Industrial UHF
Страница 1: ...BLUEBOX CX Industrial UHF Page 1 of 126 UHF RFID System BLUEBOX CX Industrial UHF...
Страница 80: ...BLUEBOX CX Industrial UHF Page 80 of 126 7 1 2 Wiring 5326U opt1 rrr 7 1 3 Wiring 5327U rrr a1 b c1 a1 b d...
Страница 105: ...BLUEBOX CX Industrial UHF Page 105 of 126 13 13 Mechanical Drawings 5348U opt1 rrr All the dimensions are in mm...
Страница 122: ...BLUEBOX CX Industrial UHF Page 122 of 126 5 On the next screen choose Advanced Options...
Страница 123: ...BLUEBOX CX Industrial UHF Page 123 of 126 6 Then click on Startup Settings...
Страница 126: ...BLUEBOX CX Industrial UHF Page 126 of 126...