BLUEBOX CX Industrial UHF
Page 62 of 126
Parameter
Description
R->T Bit
Coding
R->T bit coding:
•
0x00: FM0;
•
0x01: Miller 2;
•
0x02: Milller 4;
•
0x03: Miller 8.
Note that allowed values are:
R->T Link Frequency
R->T Bit Coding
40 kHz
FM0, Miller 2, Miller 4, Miller 8
160 kHz
FM0, Miller 2, Miller 4, Miller 8
256 kHz
Miller 4, Miller 8
320 kHz
Miller 4, Miller 8
640 kHz
Miller 4, Miller 8
DRM (Dense Reader Mode):
R->T Link Frequency
R->T Bit Coding
256 kHz
Miller 4, Miller 8
320 kHz
Miller 4, Miller 8
EPC Size
The size of the recognized EPC in bytes. 0 means all EPC sizes.
Use AFI
To enable/disable the AFI (Application Family Identifier) management:
•
0x00: Disabled;
•
0x01: Enabled.
AFI
The AFI (Application Family Identifier) value.
The parameters 1…14 fields with default values of page 0x82 are:
1
2
3
4
5
6
7
ReadAfterD
etect
Password0
ReadAfterD
etect
Password1
ReadAfterD
etect
Password2
ReadAfterD
etect
Password3
ReadAfterD
etect Bank
ReadAfterD
etect
Address0
ReadAfterD
etect
Address1
0x00
0x00
0x00
0x00
0x00
0x00
0x00
8
9
10
11
12
13
14
ReadAfterD
etect
Address2
ReadAfterD
etect
Address3
ReadAfterD
etect
Length
ReadAfterD
etect Info
Flags
Q
Q Adjust
Rounds
Inventory
Cycles
0x00
0x00
0x00
0x03
0x05
0x03
0x03
Содержание IDTRONIC CX Industrial UHF
Страница 1: ...BLUEBOX CX Industrial UHF Page 1 of 126 UHF RFID System BLUEBOX CX Industrial UHF...
Страница 80: ...BLUEBOX CX Industrial UHF Page 80 of 126 7 1 2 Wiring 5326U opt1 rrr 7 1 3 Wiring 5327U rrr a1 b c1 a1 b d...
Страница 105: ...BLUEBOX CX Industrial UHF Page 105 of 126 13 13 Mechanical Drawings 5348U opt1 rrr All the dimensions are in mm...
Страница 122: ...BLUEBOX CX Industrial UHF Page 122 of 126 5 On the next screen choose Advanced Options...
Страница 123: ...BLUEBOX CX Industrial UHF Page 123 of 126 6 Then click on Startup Settings...
Страница 126: ...BLUEBOX CX Industrial UHF Page 126 of 126...