BLUEBOX CX Industrial UHF
Page 33 of 126
o
tag_id
: ID of the tag (s
ee tag’s ID specifications).
o
rssi
: The detection
tag’s signal RSSI I and Q measured values in dB
(optional variable present only if the RSSI information flag in
the RF parameters is active).
o
antenna
: the detection antenna info
(optional variable present
only if the reading antenna information flag in the general
parameters is active)
:
▪
0x01 -> Antenna 1.
▪
0x02 -> Antenna 2
o
direction
: the gate crossing direction
(optional variable present
only if ‘gate’ mode is active)
:
▪
0x01 -> Crossing from input 1 to input 2.
▪
0x02 -> Crossing from input 2 to input 1.
o
timestamp
: the detection timestamp. BCD coded with the following
format yyyyMMddhhmmss. In case of no RTC or RTC error this field
is filled with 0xFF bytes.
(optional variable present only if the
timestamp information flag in the general parameters is
active)
.
•
If configured and avaiable
an host can wait for incoming ‘spontan
e
ous’
messages through Wieagand interface.
The ‘spontaneous’ me
ssage is sent
only once and no ACK/NAK reply message is implemented except of the
normal TCP handshake mechanism, see the protocol manual for details.
•
If configured and avaiable an host can wait for incoming ‘spontaneous’
messages through CAN bus. The ‘spontaneous’ message is sent only once
and no ACK/NAK reply message is implemented except of the normal CAN
bus handshake mechanism, see the protocol manual for details.
•
If configured and available an host can connect the reader on the
configured Bluetooth connection
and wait for ‘spontaneous’ messages. The
‘spontaneous’ message is sent
only once and no ACK/NAK reply message
is implemented except of the normal Bluetooth handshake mechanism,
see the protocol manual for details.
In case of a ‘spontaneous’ message send error, due to a connection
or communication error, no further attempts will be made and the
tag will be discarded!
Содержание IDTRONIC CX Industrial UHF
Страница 1: ...BLUEBOX CX Industrial UHF Page 1 of 126 UHF RFID System BLUEBOX CX Industrial UHF...
Страница 80: ...BLUEBOX CX Industrial UHF Page 80 of 126 7 1 2 Wiring 5326U opt1 rrr 7 1 3 Wiring 5327U rrr a1 b c1 a1 b d...
Страница 105: ...BLUEBOX CX Industrial UHF Page 105 of 126 13 13 Mechanical Drawings 5348U opt1 rrr All the dimensions are in mm...
Страница 122: ...BLUEBOX CX Industrial UHF Page 122 of 126 5 On the next screen choose Advanced Options...
Страница 123: ...BLUEBOX CX Industrial UHF Page 123 of 126 6 Then click on Startup Settings...
Страница 126: ...BLUEBOX CX Industrial UHF Page 126 of 126...