Parameter
Description
•
0x0C: Message is sent like in option 6 with an STX char at the begin of the
message.
Encoding
The ‘spontaneous’ message encoding:
•
0x00: None;
•
0x01: Decimal.
3.2.9
RF and EPC C1G2 (Class-1 Gen-2)
This section provides details on the configurable RF and EPC C1G2 (Class-1 Gen-
2) parameters of the
BLUEBOX
Parameter
Description
Range
Default
RF
Geographical
Region
RF geographical region.
Note that ETSI, FCC and Brazil readers cannot
be altered and only operate per the regulatory
laws in USA/Canada, the European Union and
Brazil.
EU1: ETSI
FCC: FCC
BRA: Brazil
EU1: ETSI
FCC: FCC
BRA: Brazil
RF Trasmit
Power
RF conducted transmit power in dBm.
Refer to country specific regulations for
limitations. You, the user, are responsible to
ensure operation with the correct RF settings and
are solely responsible for any fines and other
damages due to incorrect or non-compliant
country/region settings.
(See the
technical
specifications
section)
20 dBm
RF Receive
Sensitivity
RF receive sensitivity in dBm.
-
49 …
-85 dBm
-76 dBm
RF Channel
RF channel.
Note that 0 value stands for default settings
of the selected region.
Refer to country specific regulations for
channel allocation within the band. You, the user,
are responsible to ensure operation with the
correct RF settings and are solely responsible for
any fines and other damages due to incorrect or
non-compliant country/region settings.
EU1:
0 …
10
F
CC: 0 … 50
BRA: 0 … 50
0
Antenna 1
Activation
Activation of antenna 1.
Disabled
Enabled
Enabled
Antenna 2
Activation
Activation of antenna 2 (for devices with up to 2
antennas).
Disabled
Enabled
Disabled
RF Channel
Allocation
Time
The maximum period of consecutive transmission
on the same RF channel.
0.00 … 0.99
seconds
0
Содержание IDTRONIC CX Industrial UHF
Страница 1: ...BLUEBOX CX Industrial UHF Page 1 of 126 UHF RFID System BLUEBOX CX Industrial UHF...
Страница 80: ...BLUEBOX CX Industrial UHF Page 80 of 126 7 1 2 Wiring 5326U opt1 rrr 7 1 3 Wiring 5327U rrr a1 b c1 a1 b d...
Страница 105: ...BLUEBOX CX Industrial UHF Page 105 of 126 13 13 Mechanical Drawings 5348U opt1 rrr All the dimensions are in mm...
Страница 122: ...BLUEBOX CX Industrial UHF Page 122 of 126 5 On the next screen choose Advanced Options...
Страница 123: ...BLUEBOX CX Industrial UHF Page 123 of 126 6 Then click on Startup Settings...
Страница 126: ...BLUEBOX CX Industrial UHF Page 126 of 126...