-8-
Revision 7/F3527
©
Moffat Ltd, November 2004
Figure 2.1
GAS CONNECTION
A ½” BSP female elbow is provided for at the
bottom of oven rear.
USA/Canada models have a ½” NPT female
connection.
A restraint chain anchor has been provided
above the gas connection point for fitment of a
restraint chain when a flexible gas line is
fitted.
It is important that adequately sized piping run
directly to the connection joint on the oven
with as few tees and elbows as possible to
give maximum supply volume.
A suitable jointing compound which resists
breakdown action of LPG must be used on
every gas connection.
Check all connections for leakages.
Check appliance rating plate for correct orifice
size and operating pressure for the gas being
installed before operation.
The appliance combination gas valve is fitted
with an internal regulator for adjusting the
operating pressure.
To access, remove appropriately marked side
service panel from bottom right side of oven.
Unscrew and remove regulator cap from gas
valve. Fit pressure gauge to pressure test
point (located at bottom right side of oven,
behind service panel). Turn on main burner,
and adjust regulator to achieve stated
pressure
whilst burner is running.
Turning
the screw clockwise increases the pressure,
whilst turning counter-clockwise decreases
the pressure.
WATER CONNECTION
A cold water supply should be fitted to the
water inlet (¾” BSP hose connection) which is
located on the rear of the right hand side of
the unit.
Alternately, a connection elbow and sealing
washer is supplied with this unit for direct
connection of a 1/2” ID hose, and is
recommended for easy installation and
service.
Connect water supply - Max inlet pressure
80psi / 550kPa.
Turn on water supply to check for leaks.
DOOR HANDLE INSTALLATION
1. Open oven door.
2. Remove two screws (item 2).
3. Remove the two screws (item 3) from the
handle (item 1).
4. Install the handle bracket through the slot
on the door side.
5. Screw in the two screws (item 2) fully,
then fully screw in the previous two
screws (item 3). Ensure that they are
tight.
IMPORTANT:
ENSURE MANUAL
ISOLATING VALVE LOCATED ON RIGHT
HAND SIDE OF OVEN BEHIND GAS
CONTROL SERVICE PANEL IS OPENED
FOR OPERATION.
IMPORTANT:
MAXIMUM INLET WATER
PRESSURE IS 550 kPa / 80 psi.
1
3
2
Figure 2.2
On initial start-up of unit check burner colour.
Burner should be bright orange after 1
minutes operation.
A draft flame plume of approximately 75mm (3
inches) of blue/orange colour is normal.
L1
L2
Ground
Phase
Neutral
RED
BROWN
BLACK
GREEN/YELLOW
GREEN
WARNING:
THIS APPLIANCE MUST
BE GROUNDED / EARTHED
BLACK
BLUE
WHITE
Содержание 203926
Страница 58: ...58 Revision 7 F3527 Moffat Ltd November 2004 11 PARTS DIAGRAMS 11 1 MAIN ASSEMBLY...
Страница 61: ...61 Revision 7 F3527 Moffat Ltd November 2004 11 2 CONTROL PANEL ASSEMBLY Mounted on item 6 Main assembly...
Страница 67: ...67 Revision 7 F3527 Moffat Ltd November 2004 11 4 GAS PIPING ASSEMBLY...