-6-
Revision 7/F3527
©
Moffat Ltd, November 2004
LOCATION
This oven must be installed in an area of
adequate air supply. The following minimum
clearances for air openings, servicing,
operation and installation are to be adhered to:
Rear
75mm / 3”
Left-hand side
75mm / 3”
Right-hand side
75mm / 3”
Top
200mm / 8”
(or 600mm from a
combustible
surface.)
Floor
127mm / 5”
OVEN INTERNAL DIMENSIONS
Width
468 mm / 18.5”
Height
533 mm / 21”
Depth
711 mm / 28”
Oven Volume 0.18 m³ / 6.3 ft³
OVEN RACK SIZE
Width
460 mm / 18”
Depth:
660 mm / 26”
GAS SUPPLY SPECIFICATION OPTIONS
Natural
LPG/Prop
(G20 UK)
(G31 UK)
Input Rating
35 MJ/hr
35 MJ/Hr
33 000 Btu/hr 33 000 Btu/hr
9.5 kW
9.5 kW
Gas Rate
0.91 m³/hr
0.67 kg/hr
32.1 ft³/hr
1.48 lb/hr
Supply
1.13 kPa
2.75 kPa
Pressure 4.5”w.c. 11.0”w.c.
(Not USA/Can/UK)
Operating
0.90 kPa
2.25 kPa
Pressure 3.6”w.c.
9.0”w.c.
(Not USA/Can/UK)
Operating
10 mbar
35 mbar
Pressure
(UK only)
Operating
1.13 kPa
2.75 kPa
Pressure 4.5”w.c. 11.0”w.c.
(USA/Can only)
GAS CONNECTION SPECIFICATIONS
½” BSP female - Not USA / Canada
½” NPT female - USA / Canada only
ELECTRICAL SUPPLY SPECIFICATION
OPTIONS
110-120 V AC, 60 Hz, 2.0 A, 1 Phase
220-240 V AC, 50 Hz, 0.7 A, 1 Phase
230-240 V AC, 50 Hz, 0.55A, 1 Phase
220-240 V AC, 60 Hz, 0.7 A, 1 Phase
ELECTRICAL PLUG SPECIFICATION
REQUIREMENTS
Australia
AS 2124, 10 Amp, 3 pin
Canada
NEMA 5-15, 15 Amp, 3 pin
New Zealand
AS 2124, 10 Amp, 3 pin
United Kingdom BS 1363A 13A fused, 3 pin
United States
NEMA 5-15, 15 Amp, 3 pin
Other Countries Type to meet country
standards
BURNER INJECTOR ORIFICE SIZE
LPG/Prop/Butane 1.70
mm
/ No 51 drill size
Propane (G31)
1.55 mm (UK only)
Natural
2.70 mm / No 36 drill size
Natural (G20)
2.60 mm (UK only)
WATER SUPPLY CONNECTION
Max Pressure 550 kPa / 5.5 bar / 80 psi
Min Pressure 100 kPa / 1.0 bar / 15 psi
AUTOMATIC IGNITION CONTROL
110 Volt Models (24 Volt ignition system)
2 re-ignition attempts after burner ignition
failure. 30 second purge time between
ignition attempts. Lock-out condition after 3
ignition failures.
2 re-ignition attempts in the event of flame
loss during burner operation. 30 second
purge time between ignition attempts. Lock-
out condition after 2 re-ignition attempt
failures.
220-240 Volt Models*
Lock-out condition after burner ignition failure.
No re-ignition attempt.
1 re-ignition attempt in the event of flame loss
during burner operation. Lock-out condition if
re-ignition failure.
*
Specifications apply to units from serial
number 203927.
NOTE:
Refer to Appendix B for further
ignition control specifications.