-36-
Revision 7/F3527
©
Moffat Ltd, November 2004
Two Screws
6.3.15 MOTOR
6.3.14 FAN
1) Remove side service panel (refer 6.1.2)
2) Remove fan (refer 6.2.16) and then
remove the wires that go to the motor.
3) Undo the three screws holding the motor
in place (from the outside) and remove
motor.
Figure 6.3.20
Spray Nozzle
2) Clean or replace as required, ensuring
debris free on re-assembly.
3) Ensure that the spray nozzle is installed in
the vertical position.
Figure 6.3.18
Figure 6.3.19
1) With baffle removed undo the centre nut.
NOTE:
LH thread - Turn clockwise to
loosen.
Screws (3)
4) Replace and re-assemble in reverse
order.
60 Hz
Terminal
50 Hz
Terminal
Earth /
Ground
Neutral
2) Replace and re-assemble in reverse
order.
Centre Nut
6.3.16 OVERTEMP THERMOSTAT
(UK UNITS ONLY)
1) Open control panel (refer 6.2.1)
2) To reset, firmly press reset button.
Figure 6.3.21
4) Remove wires from overtemp.
5) Open oven door, remove racks and fan
baffle rack. Loosen two screws securing
thermostat phial bracket.
Figure 6.3.22
Two Screws
6) Withdraw old thermostat phial through
side of oven.
7) Remove fibreglass sleeving from old
thermostat and fit to the replacement
thermostat.
8) Replace overtemp and re-assemble in
reverse order.
6.3.17 24 VOLT TRANSFORMER
(USA / CANADA UNITS ONLY)
1) Open control panel (refer 6.2.1).
2) Remove transformer wires from the
control panel and ignition box, noting their
positions.
WARNING: OVERTEMP BUTTON IS
LIVE. ISOLATE UNIT FROM POWER
SUPPLY BEFORE RESETTING.
3) To replace, remove two screws securing
overtemp thermostat to overtemp bracket.
5) Ensure wire connections are correct to the
voltage supply—60 Hz / 50 Hz (fig 6.3.20)
Содержание 203926
Страница 58: ...58 Revision 7 F3527 Moffat Ltd November 2004 11 PARTS DIAGRAMS 11 1 MAIN ASSEMBLY...
Страница 61: ...61 Revision 7 F3527 Moffat Ltd November 2004 11 2 CONTROL PANEL ASSEMBLY Mounted on item 6 Main assembly...
Страница 67: ...67 Revision 7 F3527 Moffat Ltd November 2004 11 4 GAS PIPING ASSEMBLY...