Bird Diagnostic System
70
Specifications
General Specifications
Parameter
Specification
RF power, max
Max RF power is sensor dependent. See
for max power of a standard sensor.
Frequency range
307 kHz - 252 MHz (sensor dependent)
Frequency resolution
100 Hz
Frequency accuracy
± 1 kHz
Number of fundamental tracking channels
(F
0
)
3
Number of Harmonic and Intermodulation
Product tracking channels
4 harmonics per fundamental, 6 intermodulation
products per pair of fundamentals, up to 252 MHz.
Limited by maximum number of measurement
channels.
Maximum RF Level for Voltage and Current
Inputs
+27dBm, auto gain control on
Receiver Phase Angle Measurement Range -180° to +180°
Input Attenuation Range
30 dB, 6 dB steps
Instantaneous Dynamic Range
70 dB
Processing gain
30 dB minimum
Signal-to-Noise Ratio (SNR)
65 dB
Operating Modes
Tracking Mode (CW, Pulse, Multi-Level Pulse)
Spectral Search Mode
Time Domain Mode (with license)
Mode Configuration
Via BDS UI or customer specific protocol
Interfaces
7001A900-2
7001A900-3
Ethernet
Ethernet, RS-232
Operating Power
15 VDC, 2.5 A, Limited Power Source
Temperature Derating
0.05% / °C and 0.1° / °C
Warm-up Time
15 Minutes