63
Chapter 5
Maintenance
This chapter describes routine maintenance, along with troubleshooting instructions for the Bird Diagnostic System
(BDS). For service beyond this level, return the unit to a qualified service center.
The BDS requires only simple, routine maintenance.
Wipe off dust and dirt regularly.
Check the connectors and cables for damage.
Clean the connector contacts with alcohol or dry cleaning solvent.
Cleaning
To clean the Bird Diagnostic System receiver, use only a soft cloth dampened with mild detergent and rinse with
water. Clean the sensor with alcohol or a dry cleaning solvent that leaves no residue.
Using the Web UI
The Web UI is accessed using a web browser, by entering the BDS’s IP address in the web browser.
Web UI Login
1. Connect Ethernet cable to the Ethernet Ports on the BDS Receiver and the PC.
2. Power up the receiver (wait for left and center status indicators to illuminate green).
3. Launch the Web Browser on the PC.
4. Type the IP Address for the BDS receiver into the web browser’s address bar.
BDS Default IP Address: 192.168.0.151
5. Click
Login
on the left side of the BDS Receiver’s web page.
6. Enter the Login credentials for the BDS Receiver.
Default Login: admin
Default Password: admin
Figure 59 Web UI Login Screen