Operating Instructions
45
Using Standard Tracking Mode
This section provides the minimum steps required to configure the BDS receiver in Standard Tracking Mode.
There are many settings and options available in the Standard Mode of operation.
For more information about Standard Tracking Mode options, refer to
"Standard Tracking Mode Configuration" on
.
Setting the Minimum Configuration
Note:
The minimum configuration is one fundamental frequency and no harmonics or IMD.
1. Hover the cursor over the
Mode
menu, then move cursor to
Switch Mode >
, then select
Tracking Mode (TRK)
2. At the Main menu, select
Mode
->
Options…
or click the red reticule icon in the “Options” toolbar. This will open
Standard Tracking Mode Configuration dialog box.
3. Click on the
Frequency Selection
tab to bring it to the foreground.
Figure 47 Frequency Selection
4. Select a Fundamental Group from the
Fundamental groups
Drop down list.
5. Select desired Fundamental in the
Fundamental
field list then click the
Add>>
button to add your selection to
the Selected Frequencies list at the right. Repeat to add additional fundamental frequencies.
Note:
If harmonics are desired for this fundamental frequency, click on each “H” button that
represents the harmonics you desire (e.g. H1, H2, H3, H4).
Note:
To remove a frequency or harmonic from the Selected Frequency list, select it then click the
<<Remove
button.
6. Add more fundamental frequencies and harmonics as desired. When you are finished adding frequencies and
harmonics, click the
Apply
button.