The circulation pump can be set to run for a few seconds after water has been drawn off to prevent the build-up of lime-
scale in the heat exchanger.
Setting range: On, Off / Default: see table.
Circulation time (Menu 6.9.1)
This is the time for which the circulation pump runs after water has been drawn off to prevent the build-up of limescale in
the heat exchanger.
Setting range: 5 sec to 60 secs / Default: see table.
MENU LOCK (MENU 7)
Menu “7. Menu lock” can be used to safeguard the con-
troller against unintentional changes to selected settings.
Press “esc” or select “Exit menu lock” to exit the menu.
The menus listed below remain fully accessible even
when the menu lock is active, and can be used to make
changes if necessary:
- Measurements
- Statistics
- Display mode
- Menu lock
- Service data
To lock the other menus, select “Menu lock ON”.
To re-enable the menus, select “Menu lock OFF”.
Setting range: On, Off / Default: see table.
SERVICE DATA (MENU 8)
Menu “8. Service data” can be used for the purposes of
diagnosis by the manufacturer or a technician when inve-
stigating errors, etc..
b
Use the table below to record displayed data if an
error occurs.
Press “esc” or select “Exit service data” to exit the menu.
LANGUAGE (MENU 9)
Menu “9. Languages” can be used to select the language in which menus are displayed and navigated. Selection is
prompted automatically at start-up.
The choice of languages may differ, depending on the controller model.
7.Exit menu lock
Info
7.1.Menu lock
off
esc
8.FWC3-BRV 2008/09/29.3511
Info
8.2.Hot water
45°C
8.3.Circulation
43°C
esc