Timer Description
16 character labels can be assigned to each Timer.
Power Station Management
The Control panel Bus accepts up to 8 x 2 A and/or 5 A
Power Stations.
Duress Code
This attribute allows User Codes to generate call and/or
report transmission associated events, without generat-
ing audible or visual signalling on Keypads.
Patrol Code
This attribute allows User Codes to Disarm Partitions
for the programmed Patrol Time, and Rearm them be-
fore the programmed Patrol Time expires.
User menu access
This feature allows User Codes to carry out an unlim-
ited/limited number of operations.
Autoreset on Arming
This feature allows Partitions to Reset automatically
each time they Arm.
Customized Events
This feature allows the system to manage up to 32 Cus-
tomized events. Each Customized Event will be gener-
ated by the combined effect of two other events
(selected as required) that must occur within a pro-
grammed interval (window). The Operator (
AND
,
OR
or
XOR
) of the two selected Events will determine the op-
erating mode of the Customized Event.
This feature is particularly useful in commercial buildings
where, for security reasons, two Codes must be entered
within a 2 minute window, to open a safe-room door.
Full Arming Alarm
This feature allows Zones to generate Alarms when AT
LEAST ONE of their associated Partitions is Armed.
Auto-arm on delay
This feature allows Zones to Arm their associated Parti-
tions automatically. If a Zone DOES NOT DETECT mo-
tion within a programmed interval, the system will
assume that no Users are present and will Arm the Par-
titions the Zone belongs to.
KYO 300-KYO100
APPENDIX
97
EVENT
CONTACT ID
SIA
CL. CODE GROUP ZONE
TYPE
1
st
2
nd
Alarm on zone
1
30
00
zone no. BA/BR
0000 zone no.
Tamper on zone
1
37
00
zone no. TA/TR
0000 zone no.
Fire alarm on partition
1
10 part. no.
000
FA/FR part. no.
000
24h alarm on partition
1
33 part. no.
000
BA/BR part. no.
000
Burglar alarm on partition
1
30 part. no.
000
BA/BR part. no.
000
Generic alarm on partition
1
30 part. no.
000
BA/BR part. no.
000
Tamper alarm on partition
1
37 part. no.
000
TA/TR part. no.
000
Tamper alarm on partition
1
37 part. no.
000
TA/TR part. no.
000
Away alarm on partition
1
30 part. no.
000
BA/BR part. no.
000
Stay alarm on partition
1
30 part. no.
000
BA/BR part. no.
000
Fire alarm on panel
1
10
00
000
FA/FR
0000
000
24h alarm on panel
1
33
00
000
BA/BR
0000
000
Burglar alarm on panel
1
30
00
000
BA/BR
0000
000
Generic alarm on panel
1
30
00
000
BA/BR
0000
000
Tamper alarm on panel
1
37
00
000
TA/TR
0000
000
Tamper alarm on panel
1
37
00
000
TA/TR
0000
000
Tamper on Main unit
1
37
00
000
TA/TR
0000
000
Stop-alarms jumper
3
00
00
000
RO/RC
0000
000
Balanced tamper
1
37
00
000
TA/TR
0000
000
Tamper on supervised output
3
24
00
000
YA/YH
0000
000
Tamper BPI readers
3
41
00
000
ET/ER
0000
000
Tamper BPI input expanders
3
41
00
000
ET/ER
0000
000
Tamper on keypads
3
41
00
000
ET/ER
0000
000
Tamper output expanders
3
41
00
000
ET/ER
0000
000
Tamper power stations
3
41
00
000
ET/ER
0000
000
Tamper wireless device
3
41
00
000
ET/ER
0000
000
Warning readers
3
33
00
000
ET/ER
0000
000
Table 13
Structure of the main Reporting formats supported by the System (continued ...)