Ø
If key
5
is pressed, the Control panel will play mes-
sage
59
which contains the instructions for the DTMF
menu Arm/Disarm single Partitions options, that is, the
functions of keys 0+nn and 1+nn.
Messages 55, 56, 57, 58, 59 and 60 of the Voice Guide
must be recorded by the Installer. The Voice Message
recording instructions, and some examples of typical
messages can be found in the “Voice Message” sec-
tion. For example, message 55: “Press 1 to activate Re-
mote Listen-In, press 2 to activate the 2-way Audio
channel, press # to go back to the Main menu”.
Ø
If key
7
is pressed, the Control panel will play mes-
sage
54
which contains the instructions for the DTMF
menu Record/Play Memos option, that is, key 1 (Re-
cord memo) and Key 0 (Play memo).
New Teleservice Link-up
Enable this option ONLY
when Teleservice fails to operate at default settings.
Display Zones in Alarm on Keypad
If this option is
enabled, the LCD Keypad will provide real-time infor-
mation — during Disarmed status — regarding Alarm
conditions on Zones associated with any of its Parti-
tions.
Display Chime Zone on Keypad (real-time)
If
this
option is enabled, the LCD Keypad will provide
real-time information — during Disarmed status — re-
garding Alarm conditions on
Chime
Zones associated
with any of its Partitions.
Signalling will stop when the
Zones concerned
restore automatically
to standby
status.
Display Chime Zone on Keypad (memory)
This op-
tion is irrelevant if the “Display Chime on Keypad
(real-time)” option is disabled.
If this option is enabled, the LCD Keypad will provide
real-time information — during Disarmed status — re-
garding Alarm conditions on
Chime
Zones associated
with any of its Partitions.
Signalling will continue until
the Partition concerned is
reset manually
.
+
The above-mentioned “Display … on Keypad” op-
tions will soon be available for programming via
Keypad.
Enable Continuous Recording
If this option is en-
abled, the Control Panel will use
Message No. 62
to
continuously record any sounds picked up by the micro-
phones of the Voice board and connected Micro-
phone-Speaker boards.
If any of the Events listed in the
Events enabled to
stop continuous recording
Table occurs, the Control
Panel will stop recording after the programmed
Time-
out stop continuous recording
. In this way,
Message
No. 62
will record ambient sounds picked up before and
after the programmed events (refer to “Continuous Re-
cording” in the USER MANUAL).
Events Enabled to Stop Continuous
Recording
If this option is enabled, you will be able to
select the Events that will stop the Continuous Record-
ing facility.
At default, only
Tamper alarm on partition
will stop the Continuous Recording facility.
To change an Event:
1.
Double click on the
No.
field, or on the field of the
Events enabled to stop continuous recording
.
2.
Select the required Event from the list.
3.
Click
OK
.
To delete an Event:
4.
Select the
No.
field of the Event;
5.
Press
Canc
button on the computer keypad.
Timeout Stop Continuous Recording
This field will
allow you to program the interval (in seconds) between
the start of an Event — selected on the
Events enabled
80
Figure 50
Options page