Exit delay
Violation of an
Exit delay
Zone — during
the
Exit Time
of its Partition — will not trigger any
events. In all other cases, the system will generate the
Events associated with the
Instant
Zones.
The Zones leading out of a Partition should be pro-
grammed as
Exit delay
Zones.
Last exit
Violation of a
Last Exit
Zone — during the
Exit Time
of its Partition — will not generate any Events
but will clear any residual
Exit Time
, and trigger the
programmed
Last Exit Time
of its Partition.
In all other cases, the system will generate the Events
associated with the
Instant
Zones.
This feature will allow the system to Arm as soon as the
programmed
Last Exit Time
expires.
The last Zone leading out of a Partition should be pro-
grammed as a
Last Exit
Zone.
24h
Violation of a
24h Zone
— regardless of the status
of its Partition (Armed/Disarmed) will generate the fol-
lowing events:
Ø
Alarm on zone
(relevant to the Zone in question);
Ø
24h alarm on partition
,
Generic alarm on partition
and
Tamper alarm on partition
— rele-
vant to the Partition the Zone is assigned to;
Ø
Tamper alarm on panel
,
Generic alarm on panel
and
Tamper alarm on panel
.
24h
Zones NEED NOT necessarily be assigned to Par-
titions. In which case, they will generate only:
Ø
Alarm on zone
(relevant to the Zone in question);
24h
Zones that are not assigned to Partitions can be
used for control applications, such as switching on
courtesy lights (using infrared sensors).
+
24h
Zones which are not assigned to Partitions
must be programmed as
Repetitive
(refer to
“Cycles”).
Fire
Violation of a
Fire
Zone — regardless of the sta-
tus of its Partition (Armed/Disarmed) will generate the
following events:
Ø
Alarm on zone
(relevant to the Zone in question);
Ø
Fire alarm on partition
,
Generic alarm on parti-
tion
and
Tamper alarm on partition
—
relevant to the Partition the Zone is assigned to;
Ø
Fire alarm on panel
,
Generic alarm on panel
and
Tamper alarm on panel
.
Duress
Violation of an Unbypassed
Duress
Zone which
is not in Test status, and has not run its programmed cy-
cles will generate the following Instant Events
8
:
Ø
Alarm on zone
(relevant to the Zone in question);
Ø
Panic alarm on partition (VDS) no.
—relevant to
the Partitions the Zone is assigned to.
Moreover, the Keypad:
Ø
WILL NOT signal Alarms triggered by Duress Zones
(the
a
indicator WILL NOT blink).
Ø
WILL NOT signal outgoing calls triggered by Duress
Zones (
X
WILL NOT appear above the
i
icon).
n
Command
If a
Command
Zone triggers an Alarm (see “Balance”,
“Voltage Range” and “Sensitivity”), the system will gen-
erate the programmed Actions. In all other cases (Tam-
per and Short Circuit) it will operate as an Alarm Zone.
Command
Zones will be active at all times, regardless
of the status of their Partitions (Armed/Disarmed).
Arm/Disarm/Toggle
If this command is enabled, all
the Partitions the Zone is assigned to will change status
when the Zone triggers an Alarm — Armed Partitions
will Disarm and visa versa (refer to “Partitions”).
Arm/Disarm/Bistable
If this command is enabled, all
the Partitions the Zone is assigned to will Arm — when
the Zone triggers an Alarm, and Disarm — when it re-
stores to standby.
+
Partitions — Armed by an
Arm/Disarm/Bistable
Com-
mand Zone — cannot be Disarmed until all the Zones
of that type are in standby status (and CANNOT be
Disarmed via Keypad, Reader, Telephone or PC).
Arm only
If this command is enabled, all the Partitions
the Zone is assigned to will Arm when the Zone triggers
an Alarm.
Disarm only
If this command is enabled, all the Parti-
tions the Zone is assigned to will Disarm when the Zone
triggers an Alarm.
Partition Reset
If this command is enabled, all the
Partitions the Zone is assigned to will Reset when the
Zone triggers an Alarm.
Panel Reset
If this command is enabled, the Control
panel will Reset when the Zone triggers an Alarm.
Clear Call Queue
If this command is enabled, the Call
Queue will be cleared when the Zone triggers an Alarm.
Extended Not Ready-to-Arm
If this command is en-
abled, the Zone will trigger a
Not Ready-to-Arm parti-
tion
event — relevant to its Disarmed Partitions.
Extended Ready-to-Arm
If this command is enabled,
the Zone will terminate the
Extended not
Ready-to-Arm partition
event — relevant to its Dis-
armed and Armed (
Away
mode) Partitions.
38
8
The Duress Zone will generate its respective events, regardless of the status of the Partitions it is assigned to.