thorization), or by the User (if the Control panel has
been setup to perform the automatic
Test
Event).
When the Control Panel generates a Teleservice call
(manually, by User request, or automatically via the
Callback
or
Enable Test Call
options (these options
must be Enabled), it will dial the programmed numbers
(refer to
Enable
and
Telephone number to call
) until a
call is successful, or until the programmed call
At-
tempts
cycle ends.
The layout of
Teleservice
page as follows.
Double call
This option will allow the Control Panel to
share the telephone line with another answering device
(answering machine, fax, etc.). Under normal circum-
stances, the device which allows the least number of
rings will answer any incoming calls. However, if this
option is Enabled, the Control panel will override the
other answering device when it recognizes the Double
Call sequence.
Double Call sequence:
the caller must allow no more
than 2 rings, then hang up and callback within 60 sec-
onds. The Control panel will answer on the first ring of
the second call.
+
The other answering device must be programmed
to answer after 3 or more rings.
The
B-Mod
modem manages the
Double call
option au-
tomatically.
To access the system over the phone:
ring twice and
hang up, then call the Control Panel again within 60 sec-
onds.
Callback
If this option is Enabled, the Control panel
will call the
Enabled
telephone numbers (refer to
En-
able
and
Telephone number to call
on the
Teleservice
page). In this way, ONLY authorized per-
sons can access the Teleservice facility.
Enable
This check box will allow you to Enable the
Teleservice number.
+
The application will assign the first four Telephone
Numbers in the
General book
(
Telephone
page)
to the Teleservice facility. If you do not wish to use
the preset numbers, Disable the corresponding
Enable
option.
Telephone Number to call
Select the Teleservice
Telephone Numbers from the
General book
on the
Telephone
page.
+
Disabled Telephone Numbers will not be called.
Customer Code
This Code will allow the Central Sta-
tion to identify the Control Panel.
+
Any changes made to the
Customer code
on the
Teleservice
page will affect the
Customer code
in
the
Customer Data
window and vice versa.
Attempts
This programming field will allow you to pro-
gram the maximum number of call attempts.
Valid entries: 1 through 99
At default: 8
n
Enable Test Event
If this option is Enabled, the Control panel will make
regular Test Calls. The Test call confirms that the Con-
trol Panel is operating properly. If the Control panel fails
to transmit to the Central station for a long period, it may
mean:
— the system is operating properly but no events have
occurred or,
— there is a breakdown in transmissions.
If the Central station does not receive the Test Call at
the set time, it will be assumed that there is a break-
down in transmissions.
To set up the Test call, use the
Test
event and/or
Teleservice, as follows.
Enable Test Call
If this option is Enabled, the Control
Panel will make the Test call at regular intervals, in accor-
dance with the
First Test
and
Repeat test event
settings.
KYO 300-KYO100
PROGRAMMING
57
Figure 41
Voice Messages page