If the Partition of the Zone is Disarmed, the
Ex-
tended not Ready-to-Arm partition
event will ter-
minate when ALL the trigger events terminate
(refer to
Extended not Ready-to-Arm partition
event under “Events-Actions”).
When the Zone restores to standby, it will generate an
Extended not Ready-to-Arm partition
event — rele-
vant to its Disarmed Partitions.
+
If the Partition of the Zone is Armed in Away mode,
the
Extended not Ready-to-Arm partition
event
will terminate when the
Extended Ready-to-Arm
Delay
expires (refer to “Extended Ready-to-Arm
Delay” under “Partitions”).
n
Attributes
+
The following attributes apply to
Alarm Zones
ONLY.
Unbypassable
Zones with this attribute cannot be By-
passed.
Chime
Violation of a Zone with this attribute — during
Disarmed status of its Partition will generate the
Chime
on partition no.
event, and an audible signal (beep) on
the assigned Keypads. Violation of a
Chime
Zone —
during Armed status of its Partition will trigger the Ac-
tions programmed for the
Type
parameter.
+
The
Chime
Attribute is ineffective on
24h
and
Fire
Zones.
Test
Violation of a
Zone with this attribute will not
generate the Alarm on zone no.
event. However, the
“Alarm - Zone under test”
message will be recorded in
the Control panel Logger. The
Test
phase will allow you
to check the functionality of the Zones without triggering
Alarm signals. At default, the Control panel will record
ONLY the Events that occur during Armed status. How-
ever, by means of the relevant option, events that occur
during Disarmed status can also be recorded (refer to
the
Options
page).
+
The
G
LED on the keypad will blink when there is
one or more Unbypassed Zones is in Test status.
Autobypassable
Zones with this attribute will be by-
passed automatically, if violated during Armed status of
their Partitions. They will be unbypassed when their
Partitions are Disarmed.
+
The
Autobypassable
attribute is ineffective on
Delayed Exit
Zones.
A
The IMQ SECURITY SYSTEM Approval applies
only
when
the
Enablement
of
the
Autobypassable
attribute is Disabled for Zones
with Intrusion, Tamper or Burglar detection.
Autobypass with Reset Unbypass
Zones with this
attribute will be bypassed automatically, if violation oc-
curs when their Partitions are Armed. They will be
unbypassed when standby is restored.
A
The IMQ SECURITY SYSTEM Approval applies
only when the
Autobypass with Reset Unbypass
attribute is Disabled for Zones with Intrusion, Tam-
per or Burglar detection.
Stay
Zones with this attribute will be bypassed when
their Partitions Arm in Stay mode or Stay with Zero De-
lay mode.
Delayed on Stay Arming
This Attribute can be as-
signed to
Entry Path
Zones ONLY. Zones with this at-
tribute will operate as
Delayed Entry
Zones when AT
LEAST ONE of their Partitions is in Stay mode.
Delayed and Estimated on Ready to Arm
This At-
tribute can be assigned to
Delayed Exit
and
Last Exit
Zones ONLY. If a Zone with this Attribute is NOT in
standby status when the system receives a command
to Arm one of its Partitions, it will generate a
Not Ready
to Arm
event.
n
Balance Type
The Balance Type determines the electrical state (on
the Zone input terminal) that will trigger Alarms.
+
The following electrical states must be present on
the Zone Input terminals for at least 0.3 seconds.
Normally Open
Zones with this attribute will trigger
Alarms when they short to Negative (e.g. Fire detectors).
A
The IMQ SECURITY SYSTEM Approval applies
only when the Zones are programmed as Normally
Closed (Normally Open Zones are not protected
against wire cutting).
Normally Closed
Zones with this attribute will trigger
Alarms when they Open.
A
If Zones are programmed as Normally Closed, the
IMQ SECURITY SYSTEM Approval will be down-
graded from Grade
II
to Grade
I
(Normally Closed
Zones are not protected against short circuits).
KYO 300-KYO100
PROGRAMMING