3.
Select the parameters to be downloaded, as fol-
lows:
– select
Parameters
from the
Settings
menu;
– enter a valid
Installer code
in the
Installer code
field;
–select the Control panel type from the
Panel type
menu;
–select the relevant firmware release from the
Firmware Release
menu;
– click
OK
.
4. To download a specific page
: click the
Download
button on the page in question.
5. To Download several pages
:
– select the required page from the
Folders
menu,
right click, select
Tag
(a
ü
on the page Icon indi-
cates that it will be downloaded);
– repeat the procedure for all the required Pages;
– right click again then select
Download
.
+
To download a family of pages, select the root.
!
If you send the User page with other pages, the
Control panel WILL STORE the Description, En-
abled Partitions, Associated Timers, User Menu
Access and Code type parameters, but WILL NOT
STORE the Available status, Active status, Duress
Code, Patrol Code and Father Code parameters.
+
If changes to the Descriptions are not shown on the
Keypads, use the
Broadcast Keyp.command
from the INSTALLER MENU.
For example: – to download all the Configuration re-
lated pages, select
Configuration
from the
Folders
menu; to download
All
the Pages, select
KYO 300
(or
KYO 100
) from the
Folders
menu.
6.
To view the parameters of the connected Control
Panel, work carefully through point
4.
then select
Upload
instead of
Download
.
Remote Downloading
You can download the programming data via telephone
line, using a
B-Mod
or
B-Mod/RX
modem, as follows.
+
Telephone access requires entry of the Installer code
PIN, and will ONLY be allowed when the Teleservice
option has been Enabled by the User (refer “En-
able/Disable Teleservice” in the USER’S MANUAL).
1.
Using the serial cable (the same as used for On-site Down-
loading),connecttheModemtooneofthePCserialports.
2.
Select the PC serial port for connection with the
Modem, as follows:
– select
Serial Ports
from the
Settings
menu;
– select the serial port (
Modem
section);
– select
OK
.
3.
Select
Connecting
from the
Modem
menu: this
command will open the
Connecting
window (see
Figure 54).
4.
Program the following parameters:
–
Telephone Number
– enter the Control panel
telephone number;
–
Disable Tone Check
– Enable/Disable this op-
tion as required.
If this option is Enabled, the Modem will not check
for the dialling tone before dialling;
–
Double call
– refer to the
Teleservice
page;
–
Call back
– refer to the
Teleservice
page;
–
Installer Code
– enter a valid Installer code PIN
(enabled for Downloading)
When the
Connecting
window opens, the above pa-
rameters (except for
Disable Tone Check
) will have
the programmed settings.
+
The parameters in the
Connecting
window can be
changed temporarily without affecting the pro-
grammed parameters of the open Customer.
5.
Press
Dial
: the connection status will be shown in
the box at the bottom of the
Connecting
window
(refer to “Messages”). If the connection is com-
pleted properly, the following message will be
shown:
KYO 300 ACK
01.00
CONNECTION
6.
Select
OK
: the
Connecting
window will close.
At this point, it will possible to download/upload
to/from the connected Control panel.
7.
To program and view the parameters of the con-
nected Control panel, work carefully through steps
4.
and
5.
in the “On-site Downloading” section.
8.
Select
On-hook
from the
Modem
menu to end the
connection.
Messages
The connection status will be shown in the
box at the bottom of the
Connecting
window, as follows.
KYO 300-KYO100
PROGRAMMING
89
Figure 54
Connecting Window