68
EVENT
STARTS WHEN...
ENDS WHEN...
0940
(0514)
Standard
time/Summer
time changed
...the
Enable automatic update standard
time/summer time
option is enabled and:
the Control panel clock reaches 02.00
hours on the last Sunday in March (switch
to daylight saving time) or,
at 03.00 hours on the last Sunday in Octo-
ber (switch back to standard time)
...the
[
Upd.leg.sum.time
]
message is
shown on a keypad display in View Trouble
mode
0941
(0515-
0530)
0972
Not
Ready-to-arm
partition no.
...the Partition Disarms AND:
at least one of the
Extended not
Ready-to-Arm
Command Zones associated
with the Partition detects Alarm conditions OR,
at least one of the Zones of the Partition detects
Alarm conditions and the Zone IS NOT:
— Bypassed or being Tested
— an
Exit delay
or
Last exit zone
—
Autobypassable
or
Autobypass with
reset unbypass
or
Delayed and esti-
mated on ready to arm
(the event may be
triggered with a delay of up to 2 seconds)
...ALL the Zones listed in the “STARTS
WHEN” field restore to standby (the event
may take up to 2 seconds to end)
0973
(0531-
0546)
1004
Extended not
Ready-to-Arm
partition no.
…the Partition Disarms AND:
ALL the
Extended Ready-to-Arm
Com-
mand Zones associated with the Partition
restore to Standby OR,
one of the following events occurs:
Not Ready-to-arm partition no.
,
Tamper
on Main unit
,
Balanced tamper
,
Tamper
on supervised output
,
Warning mains
failure on Power station
,
Warning low
battery on Power station
,
Warning
power trouble on Power station
,
Memory
balanced tamper
,
Memory tamper on
main unit
,
Memory tamper supervised
output
,
Warning generic
,
Memory alarm
on partition no.
,
Memory tamper on parti-
tion no.
...the Partition Disarms AND:
ALL the listed events clear, AND at least
one
Extended Ready-to-Arm
Command
Zones belonging to the Partition generates
an Alarm
... the Partition is Armed in Away Mode
AND,
at
least
one
Extended
Ready-to-Arm
Command Zone belonging
to the Partition generates an Alarm OR,
terminates the
Extended Ready-to-Arm
Delay
for the Partition.
1005
(0547-
0562)
1036
Partial arming
partition no.
...the Partition Arms in Stay Mode with Zero
Delay
...the Partition Arms in Away Mode or Dis-
arms
1037
(0563-
0578)
1068
Global arming
partition no.
…the Partition Arms in Away Mode
...the Partition Arms in Stay Mode or Stay
Mode with Zero Delay
1069
(0579-
0594)
1100
Disarming
partition no.
...the Partition Disarms
...the Partition Arms in Away Mode or Stay
Mode or Stay with Zero Delay Mode
1101
(0595-
0610)
1132
Exit time on
partition no.
...the Partition Arms in Stay or Away Mode ...the Partition Output Time expires
1133
(0611-
0626)
1164
Entry time on
partition no.
...one of the
Entry delay
Zones belonging
to the Partition detects Alarm conditions
and the Partition is Armed in Stay or Away
Mode
...the Partition Input Time expires or the
Partition Disarms
1165
(0627-
0642)
1196
Autoarming
warning
partition no.
…the Control panel signals the start of the
programmed Auto-Arm Timeout prior to Au-
tomatic Arming of the Partition
...the Partition Arms or an Overtime Re-
quest is made for the Partition
1197
(0643-
0658)
1228
Memory alarm
on partition no.
...the
Generic alarm on partition no.
Event occurs
...the Partition Resets
Table 8
Generic Events — The Event numbers for
KYO 100
are those in brackets
(
....
)