bellagio Digital Entry System
PD
–
281 Issue 1
Installation and Operating Manual
Page 38 of 52
Programming flat addresses
The address is the flat number which is entered at the entrance panel in order to call a
resident. These ad
dresses are programmed on each of the Isolator PCB’s by selecting the
positions of the rotary switch SW6 and the 8-way dipswitch SW7. In the simplest scenario
SW6 selects the address of the first phone on the isolator whilst the addresses of the other
seven phones follow in sequence as shown in the table below:
SW6
Setting
Phone address
(SW7:1-8 = OFF)
Phone
1
Phone
2
Phone
3
Phone
4
Phone
5
Phone
6
Phone
7
Phone
8
0
<address not set> (factory default)
1
1
2
3
4
5
6
7
8
2
5
6
7
8
9
10
11
12
3
9
10
11
12
13
14
15
16
4
13
14
15
16
17
18
19
20
5
17
18
19
20
21
22
23
24
6
21
22
23
24
25
26
27
28
7
25
26
27
28
29
30
31
32
8
29
30
31
32
33
34
35
36
9
33
34
35
36
37
38
39
40
A
37
38
39
40
41
42
43
44
B
41
42
43
44
45
46
47
48
C
45
46
47
48
49
50
51
52
D
49
50
51
52
53
54
55
56
E
53
54
55
56
57
58
59
60
F
57
58
59
60
61
62
63
64
Basic Addressing
In the most basic numbering scheme each isolator in the system has SW6 set to a
different value to create a continuous range of flat addresses:
E.g. 32-way system numbered 1-32
Isolator
SW6
position
Address
range
First
1
1-8
Second 3
9-16
Third
5
17-24
Fourth
7
25- 32