bellagio Digital Entry System
PD
–
281 Issue 1
Installation and Operating Manual
Page 24 of 52
Commissioning
Settings
1. Set the flat addresses of each DBA-4I or DBA-8Z Isolator referring to the following
sections.
2. Entrance and caller settings (speech time, ring time, unlock time, etc) are adjusted
through each entrance panel at the associate entrance.
Refer to the ‘Entrance
panel programming’ section page
3. Settings specific to each phone, such as ring volume and buzzer mute time, when
available, are set inside each phone with a jumper or Dipswitch.
Refer to the ‘Phone
Settings’ section.
4. Speech levels are adjusted at each entrance panel behind the speech grill, with a
separate adjustment for each direction of speech. A howling or whistling sound may
indicate the volumes levels are set to high.
Testing / Connecting
The major components of the
Digi
bell system are fitted with high quality pluggable screw
terminal blocks. This enables all the connections to the system to be fully completed,
whilst easily isolating individual pieces of equipment during testing and commissioning.
Any problems can be resolved by rechecking wiring and connections, assisted by the
various suggestions and tests in the section ‘Troubleshooting’.
Connect up one entrance first, leaving any connection to Isolators or phones unplugged:
1. When powered up for the first time, it is recommended that only the most basic
system is connected, i.e. 4/8 phones, 1 BSD-DIG Door controller and entrance
panel, 1 DBA-xx Isolator, the remaining equipment can be isolated by removing
terminal blocks.
2. Check the display and buttons on the entrance panel work as expected.
3. If there is an exit button check the door will unlock.
4. Proceed to test the system by calling each phone from the entrance panel in the
normal way, check any available phone features such as buzzer mute or door
status. Once the basic system is fully functioning, continue to connect and test
equipment item by item until completed.