bellagio Digital Entry System
PD
–
281 Issue 1
Installation and Operating Manual
Page 27 of 52
TRADE FUNCTION
–
Door Button Trades Mode
Choose the Mode value 0-9
Setting
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
Time Clock Off None None None None Code
Code
Code Trade Trade Door
Time Clock On None Door Code Trade Trade
Door
Code Trade Door Door
‘None’
= No function; pressing the
door
button is ignored.
‘Door’
= Pressing the
door
button opens the door.
‘Code’
= Pressing the
door
button prompts for the Access Code to open the door.
‘Trade’
= Pressing the
door
button prompts for either the Access Code or Trades Code
to open the door.
DOOR MON POL
–
Door Status Switch
[Owc]
= Contacts open when door is closed:
–
The default allows for no switch fitted.
[Cwc]
= Contacts closed when door is closed:
–
Standard normally closed switch.
RECPTION No
–
Reception Phone Address
The
reception
button is used to call a reception desk or similar. The number is that of the
called phone. The default is [9898] which is unlikely to be used by a flat.
SECURITY CODE
–
Panel Security Key
The security key is required to gain access to panel programming.
The code is entered then pressing the
bell
button, the default is [3434] and it is
recommended that this be changed for security.
This code can contain letters and numbers for added security.
PHONE CODE
–
Phone Programming Security Key
The phone programming security key is required to gain access to flat number
programming of telephones. The default is [1212] and it is recommended that this be
changed for security.
This code can contain letters and numbers for added security.
This function is for when the BFD-DIG is used in systems where isolator programming
cannot cope with the required complexity.