bellagio Digital Entry System
PD
–
281 Issue 1
Installation and Operating Manual
Page 29 of 52
CANCEL
–
Cancel Key Compatibility
For use with a new controller in older systems with any BSC4 video Controller below Build
4, or BS801 audio phone below Build 6, or BC801 or BC801P audio phones below Build 6.
These older systems are not capable of cancelling a call and the phones will continue to
ring even though the door controller has closed down.
If this situation applies then ensure
“Cancel”
is set to [No] otherwise the default is [Yes].
BELLCALL
–
Bellcall Compatibility Mode
For use in mixed systems with a BCP1 panel revision V2.0 upwards. Switching
compatibility mode to [Yes] changes the number format for addressing a phone and
removes the 3 Second overhang of speech when operating the lock from a phone.
BS801 audio phones from Build 6, or BC801 or BC801P audio phones from Build 6, and
all BSA phones already have number format transparency built in and do not need this
switch.
Default is [No], set to [Yes] only when in a mixed BCP1 with older phones.
Must be set to [No] when addressing any apartment station or videophone.
12A TO 13
–
Flat 13 Numbered as 12A
For use when flat numbering is … 11, 12, 12A, 14, 15 … When set to [Yes] entering “12A
bell
” will actually send “13” so that the
BSC4’s can be set to respond to … 11, 12, 13, 14,
15 …
RECEPTION
–
Is Reception Button Allowed
This is used in conjunction with the Bellagio Panel Dip Switch setting to enable the display
of the reception function.
BFD-DIG Door Controller Jumper Settings
No settings relevant to an audio only system.