bellagio Digital Entry System
PD
–
281 Issue 1
Installation and Operating Manual
Page 42 of 52
Diagnostic LEDs
LED
State
Action on LED
Status
Power up
Flashes 3 times
Data is present on Data A/B.
Brief flash
Phone lock button pressed during a call or test
On for 3 secs
Test button pressed and system idle
Brief flash
Restoring factory defaults
On for 2 secs
Speech
Speech active (call in progress);
Ring Test active (no speech)
On
Off-hook
1 or more phones are off hook
On
LED1
1
st
Phone active
On
LED2
2
nd
Phone active
On
LED3
3
rd
Phone active
On
LED4
4
th
Phone active
On
LED5
5
th
Phone active
On
LED6
6
th
Phone active
On
LED7
7
th
Phone active
On
LED8
8
th
Phone active
On
Fuses
The 12V connection (V on either terminal block) is fused with a standard 20mm fuse,
which will need replacing if it fails.
There is also an electronic fuse to protect again shorts on the door monitor / contact
terminal L. This will reset once the short is removed.